Skins

Tìm kiếm

PCCC, Phòng cháy chữa cháy

Kết quả tìm kiếm trên "Sản phẩm": 10
...other is to actuate a group of alarm bells depending on the location of a fire, called localized alarm. One pair of terminals is available for the general alarm. The programmable 10 voltage-free contacts are used for the localized alarm. Automatic self-checking The following are...
...other is to actuate a group of alarm bells depending on the location of a fire, called localized alarm.. One pair of terminals is available for the general alarm. The programmable 20 voltage-free contacts are used for the localized alarm.. Automatic self-checking. The following are...
...If no Supervisory circuits are enabled, the Supervisory relay becomes a second Alarm relay. The cabinet is available in a beige color for the Canadian market and a red exterior for the U.S. and International markets. A Fire Retardant Lexan Window in the hinged door allows for viewing...
...powers the system and supplies two 4-wire resettable regulated smoke power supply of 24 VDC 200mA maximum each. The HMCC-1024-6S also allows for the addition of two HSGM-1004 Signal Modules or two HRM-1008 Relay modules in place of the HDM-1008 Initiating Circuit Adder Modules. (Maximum of...
...no wasted oil and a coolant circulation system (optional) eliminates emission of water, archieving a consistenly clean cooling solution. For the first time in a fire fighting pump, a revolutionary automatic decompression system has been added to the angine, which reduces recoil force ...
...system can be considerable enhanced with the introduction of foam solution into the systems water supply. Enhanced foam Deluge systems are ideal for the protection of hazards such as the storage and handling of flammable liquids in aircraft hangars, oil refineries and chemical plants etc. A...
...all possible corrosive environments. Prior to installation, verify through  the end-user that the coatings are compatible with or suitable for the proposed environment. The coatings indicated are applied to the exposed exterior surfaces only and,  therefore, the sprinklers cannot be...
...all possible corrosive environments. Prior to installation, verify through  the end-user that the coatings are compatible with or suitable for the proposed environment. The coatings indicated are applied to the exposed exterior surfaces only and,  therefore, the sprinklers cannot be...
...can generate heat. Do not install sprinklers where they could be exposed to temperatures exceeding the maximum recommended ambient temperature for the temperature rating used. F. Wet-pipe systems must be provided with adequate heat. Sprinklers supplied from dry systems in areas subject to...
...can generate heat. Do not install sprinklers where they could be exposed to temperatures exceeding the maximum recommended ambient temperature for the temperature rating used. F. Wet-pipe systems must be provided with adequate heat. Sprinklers supplied from dry systems in areas subject to...